|Home|Technical - Quality |
||||||||||||||||||||||||||||||||||||
|
|
Paragon has a NAMAS accredited laboratory and issues monthly test certificates to all clients. In addition, it offers technical back up for all clients and can provide samples for testing.
|
|||||||||||||||||||||||||||||||||||
Strength class |
Compressive strength MPa |
Initial Setting Time min |
Sound-ness
Expansion mm |
|||
Early strength |
Standard
strength |
|||||
2 days |
7 days |
28 days |
||||
52.5 N |
>= 20.0 |
n/a |
>= 52.5 |
n/a |
>= 45 |
<=10 |
| BS EN 197-1:2000 Chemical
requirements (% by mass of final cement) |
| Loss on ignition | <= 5.0% |
| Insoluble residue | <= 5.0% |
| Sulphate content (as SO3) | <= 4.0% |
| Chloride content | <= 0.1% |